Smell gas or hear a CO alarm? Leave now and call 911 or your gas utility from outside.

Balboa hot tub error code

Balboa hot tub code LF / M017: Low flow, heater disabled

Balboa spa controls

What LF means

Not enough flow through the heater, so the heater has been disabled. Fix the flow problem, then press any button to reset.

Also shown as: M017, depending on the model.

Likely causes

  • Dirty filter
  • Low water
  • Closed valves or jets
  • Airlock

Safe first checks

  1. Turn the spa off at the breaker, clean or remove the filter, and top up the water.
  2. Open jets and valves, restore power and press any button.

When to stop

If LF returns with good flow, call for service.

Parts that may help

Only order a part once the checks above point to it, and match the part number to your model.

Checked against: Balboa TP500S / TP600 system user guide (42339 rev A1): message codes; Balboa Spa Touch 3 user guide: messages. Codes can differ by model and year, so confirm with your owner's manual.