Smell gas or hear a CO alarm? Leave now and call 911 or your gas utility from outside.

Balboa hot tub error code

Balboa hot tub code HFL / M016: Heater flow reduced

Balboa spa controls (TP500S, TP600, Spa Touch 3)

What HFL means

Heater flow is reduced: there may not be enough flow through the heater. Heater start-up tries again after about 1 minute.

Also shown as: M016, depending on the model.

Likely causes

  • Low water level
  • Dirty filter
  • Closed valves or too many closed jets
  • Air trapped after a refill

Safe first checks

  1. Top up the water to the fill line.
  2. Turn the spa off at its GFCI/breaker, take out the filter and clean it, then restart.
  3. Open all jets and valves, and prime the pumps if you just refilled.

When to stop

If HFL stays with a clean filter and full water, call for service.

Parts that may help

Only order a part once the checks above point to it, and match the part number to your model.

Checked against: Balboa TP500S / TP600 system user guide (42339 rev A1): message codes; Balboa Spa Touch 3 user guide: messages. Codes can differ by model and year, so confirm with your owner's manual.